Connecting the New-Style Rotax 912 Oil Pressure Sensor to the EFIS

Connecting the New-Style Rotax 912 Oil Pressure Sensor to the EFIS

Attached is the manual for connecting the New-Style Rotax 912 Oil Pressure Sensor to the XTreme, Enigma, Voyager or Odyssey EFIS. This sensor is made by Honeywell.

Note: when using the RDAC XF, you do not need to install the 100 ohm resistor - you just turn the RDAC Oil P PD (pull down) dipswitch into the ON position, which connects the input to Ground via a 100 ohm resistor.






NOTE: In mid 2013 Rotax introduced new oil pressure sensor by Keller. It has the same 4-20mA output and wiring of the Honeywell sender, but is sometimes delivered without the connector terminated
:


Pin A – Not connected
Pin B – Connected to positive bus 8 – 28 volts, use fuse or circuit breaker
Pin C – Output signal is to be connected to the instrument


    • Related Articles

    • UMA Fuel Pressure Sender Settings and Wiring

      Attached are settings and wiring connections for the UMA Fuel Pressure Senders. This can be used to help if you are experiencing problems or if you suspect your fuel pressure sender is reading incorrectly.  Remember to follow these 3 Steps when ...
    • AeroVee Engine Sensor Setup

      AeroVee (Sonex) Sensor Settings AeroVee uses the following sensors: CHT: Type-K or Type-J Thermocouple (Specified at ordering) EGT: Type-K Thermocouple Oil Pressure: VDO 5-bar sensor 360-001 Oil Temperature: VDO 150-degree Celsius sensor 323-055 ...
    • Connecting a Ray Allen RAC Trim or Flap Sensor to EFIS

      Attached is the manual for attaching a Ray Allen Trim or Flap Servo Sensor to the IOX for display on an Enigma, Voyager or Odyssey EFIS ​
    • VDO Oil Pressure Sender Settings and Wiring

      Attached are settings and wiring connections for the commonly-used VDO Oil Pressure Sender. This can be used to help if you are experiencing problems or if you suspect your oil pressure sender is reading incorrectly. Remember to follow tthese 3 Steps ...
    • Connecting a Zaon XRX PCAS Traffic Monitor to your EFIS

      Attached is the manual for connecting a Zaon XRX Portable Collision Avoidance System (PCAS) to your Enigma, Voyager or Odyssey EFIS.