To setup the Westach oil temp sender as a user sender on Infinity and Velocity Singles that do not have the Westach option, you can use the following settings:



You enter these points in the User|Calibrate sender menu:

For Deg Fehrenheit: 

Points: 10
display 1: 50
ADC 1: 3270

Enter the below for points 2->10

Display, ADC
70, 2879
109, 1968
140, 1344
171, 888
190, 659
210, 488
250, 272
300, 135
400, 27

    • Related Articles

    • Westach Oil Temperature Sender

      Attached are settings and wiring connections for the Westach Oil Temperature Sender. This can be used to help if you are experiencing problems or if you suspect your oil temp sender is reading incorrectly.  This is the oil temperature sender ...
    • VDO Oil Pressure Sender Settings and Wiring

      Attached are settings and wiring connections for the commonly-used VDO Oil Pressure Sender. This can be used to help if you are experiencing problems or if you suspect your oil pressure sender is reading incorrectly. Remember to follow tthese 3 Steps ...
    • MGL Fuel Level Sender Calibration

      MGL Avionics Capacitance Fuel Level Sender Calibration  Senders are produced by Centroid Products MGL Avionics sell several standard lengths of capacitance probe (12" and 24" long). The senders can be bent above the black mark on the probe (first ...
    • UMA Fuel Pressure Sender Settings and Wiring

      Attached are settings and wiring connections for the UMA Fuel Pressure Senders. This can be used to help if you are experiencing problems or if you suspect your fuel pressure sender is reading incorrectly.  Remember to follow these 3 Steps when ...
    • Connecting the New-Style Rotax 912 Oil Pressure Sensor to the EFIS

      Attached is the manual for connecting the New-Style Rotax 912 Oil Pressure Sensor to the XTreme, Enigma, Voyager or Odyssey EFIS. This sensor is made by Honeywell. Note: when using the RDAC XF, you do not need to install the 100 ohm resistor - you ...